Give your file a name that makes it easy to identify later — include the RO tag, doc no., or revision.
The pressure does not drop in one step across an orifice. Upstream, the pressure is P₁. The jet squeezes through the bore and keeps contracting just downstream to its narrowest point, the vena contracta. The velocity is highest there, so the pressure is lowest: this is the P₂ in eq. 6.19.
Further downstream the jet spreads out again, slows down and part of the kinetic energy turns back into pressure. That part is the pressure recovery. The rest is lost for good: the fast jet mixes violently with slower, recirculating liquid behind the plate, and that turbulence turns the energy into heat. What is lost is the permanent (unrecovered) pressure loss Δϖ. The pressure has settled at its downstream value after roughly 5 – 8 pipe diameters.
| β | Lost permanently | Recovered |
|---|
The smaller the bore compared with the pipe, the more of the drop is permanent. This matches Coulson & Richardson §6.3.3: usually only about 5 – 10 % of the excess kinetic energy is recovered as pressure.
For a liquid, the lowest pressure is at the vena contracta, not downstream. That point can fall below the vapour pressure even when the downstream pressure looks safe.
The usual fix for a large liquid ΔP is a multi-stage RO: several plates in series, each taking a part of the drop so no vena contracta falls below Pv. Enter P₁ and Pv in the calculator to run this check.
Select this when the system fixes the drop between the upstream and downstream piping. This is the normal case for a restriction orifice:
Take the pressure upstream, subtract the downstream pressure and the other line losses; what is left is the Δϖ the RO must absorb. The tool converts it to P₁ − P₂ = Δϖ / (1 − β²) for eq. 6.19.
Select this when you know the differential to the vena contracta itself, for example a value from a book example or from a measurement taken at the orifice tappings.
Water at 20 °C, 5 m³/h, 2" Sch 40 line (d = 52.5 mm). The RO must take a permanent loss of 2.0 bar.
| Basis selected | Bore d₀ | P₁ − P₂ (eq. 6.19) | Real permanent loss |
|---|---|---|---|
| Permanent loss = 2.0 bar ✓ | — | — | — |
| Differential = 2.0 bar ✗ | — | — | — |
With the wrong basis the bore comes out slightly larger and the RO only burns off the lower permanent loss in the last column. At small β the difference is a few per cent; at β = 0.5 and above it becomes significant.
C&R §4.1 note that when a gas pressure changes by less than about 20 %, the gas can be treated as incompressible at the density of the mean pressure. The gas tab handles small and large pressure drops alike, so for a gas always use the gas tab.
CD depends on Re₀, and Re₀ depends on the flow, so the tool iterates: guess CD → flow from eq. 6.19 → Re₀ = ρu₀d₀/μ → new CD from Fig. 6.16 → repeat until it no longer changes. The orange point on the chart shows where CD was read.
It calculates the critical pressure ratio wc with eq. 4.26 and compares it with P₂/P₁. At or below wc it uses eq. 4.29 (critical); above wc it uses eq. 4.20 (sub-critical). The badge in the result card shows which one applied.
The graph shows the flow through an orifice at a fixed upstream pressure P₁ while the downstream pressure P₂ is lowered (the same idea as C&R Fig. 4.3). Read it from right to left:
Why the flow stops increasing. A change in pressure travels through a gas as a pressure wave at the velocity of sound. Once the gas in the orifice itself moves at that velocity, a pressure wave from downstream can no longer travel upstream against it: the upstream gas cannot "feel" P₂. Once maximum flow is reached, a further reduction in downstream pressure does not increase the mass flow rate. The pressure at the orifice remains at the critical condition, while further expansion to the downstream pressure occurs after the orifice.
| Gas (typical k) | k | wc = [2/(k+1)]k/(k−1) | Critical when P₁/P₂ ≥ |
|---|
Example 6.1 (liquid): water, 25 mm orifice in a 75 mm pipe, 300 cm³/s. The book finds about 51 mm of water.
Example 4.1 (gas): air from a cylinder at 5 MN/m² and 273 K through a 6 mm sharp-edged orifice (CD = 0.6) to atmosphere. Critical flow, about 0.210 kg/s.