Restriction Orifice Calculator
Bore Size, Flow Rate & Pressure Drop — Sharp-Edged Orifice — SI Units
Coulson & Richardson Vol. 1 Liquid: Eq. 6.19 + Fig. 6.16 Gas: Eq. 4.20 / 4.29 SI Units
Your Work
💾
Go Pro
🔒

Your 90-day free save period has ended

Nothing is lost — your inputs are still right here on screen. Upgrade to Pro to unlock Save & Open again.

€19.99 / month · cancel anytime
🔓 Unlock Save & Open — Go Pro

💾 Save your restriction orifice calculation

Give your file a name that makes it easy to identify later — include the RO tag, doc no., or revision.

📁 File will save as: RO_file.json
Special characters are replaced automatically.
Unsaved work found
Restore your last session from this browser?
💧 Restriction Orifice Calculation — Liquid
SCHEMATIC
INPUT DATA
mm
e.g. 2" Sch 40 = 52.5 mm
mm
Sharp-edged, thin plate
kg/m³
Water = 998 kg/m³ @ 20°C
cP
Water @ 20°C ≈ 1.0 cP  |  1 cP = 1 mN·s/m²
For an RO the system usually fixes the permanent loss — read the guide
bara
bara
Water @ 20°C = 0.023 bara  |  @ 100°C = 1.013 bara
📐 Formula Reference — Coulson & Richardson Vol. 1, §6.3.3
G = CD × A₀ × √[ 2 × ρ × (P₁ − P₂) / (1 − (A₀/A₁)²) ]   (6.19)
Re₀ = ρ × u₀ × d₀ / μ    u₀ = G / (ρ × A₀)
CD = f(Re₀, d₀/d)   from Fig. 6.16
Δϖ ≈ (1 − β²) × (P₁ − P₂)   permanent loss
G = mass flow (kg/s)  |  A₀ = orifice area  |  A₁ = pipe area  |  P₂ at the vena contracta  |  β = d₀/d
INTERMEDIATE RESULTS
Enter input data and click Calculate to see results.
DISCHARGE COEFFICIENT — FIG. 6.16
Sizing note: Eq. 6.19 uses the differential between the upstream pressure and the vena contracta. Only part of that is lost: the flow recovers some pressure downstream. If your system fixes the pressure drop between upstream and downstream piping, select Permanent pressure loss. For a high liquid ΔP, check cavitation; a multi-stage RO is the usual fix.
📘 Guide — Permanent Pressure Loss
WHAT IS PERMANENT PRESSURE LOSS?
0.50

The pressure does not drop in one step across an orifice. Upstream, the pressure is P₁. The jet squeezes through the bore and keeps contracting just downstream to its narrowest point, the vena contracta. The velocity is highest there, so the pressure is lowest: this is the P₂ in eq. 6.19.

Further downstream the jet spreads out again, slows down and part of the kinetic energy turns back into pressure. That part is the pressure recovery. The rest is lost for good: the fast jet mixes violently with slower, recirculating liquid behind the plate, and that turbulence turns the energy into heat. What is lost is the permanent (unrecovered) pressure loss Δϖ. The pressure has settled at its downstream value after roughly 5 – 8 pipe diameters.

P₁ − P₂Differential to the vena contracta. This is what eq. 6.19 uses.
RecoveryThe part the flow gains back as the jet slows down.
ΔϖPermanent loss = P₁ − P far downstream. This is what your piping system "sees".
HOW BIG IS IT?
Δϖ ≈ (1 − β²) × (P₁ − P₂)
Common approximation for a sharp-edged thin-plate orifice
βLost permanentlyRecovered

The smaller the bore compared with the pipe, the more of the drop is permanent. This matches Coulson & Richardson §6.3.3: usually only about 5 – 10 % of the excess kinetic energy is recovered as pressure.

WHY THE VENA CONTRACTA MATTERS

For a liquid, the lowest pressure is at the vena contracta, not downstream. That point can fall below the vapour pressure even when the downstream pressure looks safe.

CavitationP at the vena contracta < Pv, downstream > Pv. Vapour bubbles form and then collapse as the pressure recovers: noise, vibration, erosion of plate and pipe.
FlashingDownstream pressure < Pv. The liquid stays partly vapour after the orifice.

The usual fix for a large liquid ΔP is a multi-stage RO: several plates in series, each taking a part of the drop so no vena contracta falls below Pv. Enter P₁ and Pv in the calculator to run this check.

WHICH PRESSURE DROP BASIS?
Permanent (unrecovered) pressure loss

Select this when the system fixes the drop between the upstream and downstream piping. This is the normal case for a restriction orifice:

  • Pump minimum-flow line back to the suction vessel
  • Bleed or drain line to a lower-pressure system
  • Limiting flow between two vessels at known pressures

Take the pressure upstream, subtract the downstream pressure and the other line losses; what is left is the Δϖ the RO must absorb. The tool converts it to P₁ − P₂ = Δϖ / (1 − β²) for eq. 6.19.

Differential P₁ − P₂ (eq. 6.19)

Select this when you know the differential to the vena contracta itself, for example a value from a book example or from a measurement taken at the orifice tappings.

Watch out: entering a permanent loss with the Differential basis makes the RO too large: the real permanent loss is smaller than intended and more flow passes than you designed for.
HOW TO USE IT IN THE CALCULATOR
  1. Go to the Liquid tab.
  2. Choose Calculate → Bore diameter (or flow / pressure drop).
  3. Under Operating Point, set Pressure Drop Basis → Permanent (unrecovered) pressure loss.
  4. Enter the pressure drop the RO must take, and the flow.
  5. Optionally enter P₁ and Pv for the cavitation check.
  6. Click Calculate. The results show both ΔP (eq. 6.19) and Perm. loss; the step-by-step card shows the conversion.
WORKED EXAMPLE

Water at 20 °C, 5 m³/h, 2" Sch 40 line (d = 52.5 mm). The RO must take a permanent loss of 2.0 bar.

Basis selectedBore d₀P₁ − P₂ (eq. 6.19)Real permanent loss
Permanent loss = 2.0 bar ✓———
Differential = 2.0 bar ✗———

With the wrong basis the bore comes out slightly larger and the RO only burns off the lower permanent loss in the last column. At small β the difference is a few per cent; at β = 0.5 and above it becomes significant.

📗 How to Use — Restriction Orifice Formulas
LIQUID OR GAS — WHICH TAB?
💧 LiquidIncompressible flow: the density stays the same through the orifice. Uses eq. 6.19 with CD read from Fig. 6.16 as a function of the Reynolds number through the orifice.
💨 GasCompressible flow: the gas expands and cools as the pressure falls. Uses the critical pressure ratio eq. 4.26, then eq. 4.29 (critical) or eq. 4.20 (sub-critical), with CD = 0.6 by default.
NeitherTwo-phase flow, or a liquid that flashes across the orifice, is outside both methods. Use a dedicated two-phase method or the RO vendor.

C&R §4.1 note that when a gas pressure changes by less than about 20 %, the gas can be treated as incompressible at the density of the mean pressure. The gas tab handles small and large pressure drops alike, so for a gas always use the gas tab.

💧 LIQUID — STEP BY STEP
  1. Open the Liquid tab and choose Calculate: bore, flow or pressure drop.
  2. Enter the pipe inside diameter d and, unless you size it, the bore d₀.
  3. Enter density ρ and viscosity μ at flowing conditions.
  4. Choose the pressure drop basis and enter ΔP. For an RO this is usually the permanent loss — see the Permanent Loss Guide.
  5. Enter the flow (not needed when you calculate the flow).
  6. Optionally enter P₁ and the vapour pressure Pv for the cavitation check.
  7. Click Calculate.
What the tool does

CD depends on Re₀, and Re₀ depends on the flow, so the tool iterates: guess CD → flow from eq. 6.19 → Re₀ = ρu₀d₀/μ → new CD from Fig. 6.16 → repeat until it no longer changes. The orange point on the chart shows where CD was read.

💨 GAS — STEP BY STEP
  1. Open the Gas / Vapour tab and choose Calculate: bore or flow.
  2. Enter the pipe inside diameter d and, unless you size it, the bore d₀.
  3. Enter the molecular weight M, expansion index k (= γ = Cp/Cv for isentropic flow) and Z (1 for an ideal gas).
  4. Keep CD = 0.6 or enter your own value.
  5. Enter P₁ and P₂ as absolute pressures, and the upstream temperature T₁.
  6. Enter the flow in kg/h, Nm³/h, Sm³/h or actual m³/h (not needed when you calculate the flow).
  7. Click Calculate.
What the tool does

It calculates the critical pressure ratio wc with eq. 4.26 and compares it with P₂/P₁. At or below wc it uses eq. 4.29 (critical); above wc it uses eq. 4.20 (sub-critical). The badge in the result card shows which one applied.

💨 CRITICAL AND SUB-CRITICAL GAS FLOW
1.40

The graph shows the flow through an orifice at a fixed upstream pressure P₁ while the downstream pressure P₂ is lowered (the same idea as C&R Fig. 4.3). Read it from right to left:

Sub-criticalP₂/P₁ > wc. The gas in the orifice is slower than sound. Lowering P₂ increases the flow, so the flow depends on both P₁ and P₂ (eq. 4.20).
Critical / maximum flowP₂/P₁ ≤ wc. The gas reaches the critical condition at the orifice. For isentropic flow, this corresponds to sonic velocity. The mass flow reaches Gmax and does not increase with a further reduction in downstream pressure P₂.

Why the flow stops increasing. A change in pressure travels through a gas as a pressure wave at the velocity of sound. Once the gas in the orifice itself moves at that velocity, a pressure wave from downstream can no longer travel upstream against it: the upstream gas cannot "feel" P₂. Once maximum flow is reached, a further reduction in downstream pressure does not increase the mass flow rate. The pressure at the orifice remains at the critical condition, while further expansion to the downstream pressure occurs after the orifice.

Gas (typical k)kwc = [2/(k+1)]k/(k−1)Critical when P₁/P₂ ≥
WHAT IT MEANS FOR AN RO
Critical flow — a reliable flow limiter
  • The flow depends on P₁ only: Gmax is proportional to P₁ (double P₁, double the flow).
  • Changes in the downstream pressure do not change the flow, which makes the RO a robust limiter, for example for a nitrogen purge or a gas bleed to flare.
  • Expect noise and a high jet velocity downstream at large ratios; a multi-stage RO spreads the drop.
Sub-critical flow — P₂ matters
  • The flow depends on P₁ and P₂, and is most sensitive when P₂ is close to P₁.
  • Use realistic downstream pressures; a change in back-pressure changes the flow.
INPUT TIPS & LIMITS
PressuresGas: always absolute (bara). A gauge pressure gives a wrong ratio and the wrong flow regime.
kFor isentropic flow k = γ. Diatomic gases (N₂, O₂, air) ≈ 1.40; CH₄ ≈ 1.31; CO₂ ≈ 1.29.
ZC&R derive the gas equations for an ideal gas (Z = 1). Enter Z at upstream conditions for a real gas at high pressure.
CD gas0.6 default for a sharp-edged orifice (C&R Example 4.1). Use the vendor's value if you have one.
CD liquidFig. 6.16 (C&R Vol. 1) is used within the range of the applicable β-curves. Above the available high-Re curve data, CD = 0.61 is used, following the C&R recommendation for a standard orifice meter at Reo > 10⁴.
TRY THE BOOK EXAMPLES

Example 6.1 (liquid): water, 25 mm orifice in a 75 mm pipe, 300 cm³/s. The book finds about 51 mm of water.

Example 4.1 (gas): air from a cylinder at 5 MN/m² and 273 K through a 6 mm sharp-edged orifice (CD = 0.6) to atmosphere. Critical flow, about 0.210 kg/s.

Coulson & Richardson's Chemical Engineering Vol. 1, §6.3.3  ·  Sharp-edged thin-plate orifice  ·  For initial sizing only — confirm with the RO vendor