Re = ΟΒ·VΒ·D / ΞΌ β Laminar < 2300 Β· Transitional 2300β4000 Β· Turbulent > 4000
Darcy f: 64/Re (laminar) Β· Churchill (1977) otherwise
ΞP/L = fΒ·ΟΒ·VΒ² / (2D) [Pa/m] Β· ΞP_friction = ΞP/L Γ (L + L_eq)
ΞP_static = ΟΒ·gΒ·H / 10β΅ [bar] (g = 9.81 m/sΒ², H + = upward) Β· ΞP_total = ΞP_friction + ΞP_static
Utilisation = value / limit β the highest utilisation over all active cases governs the size.
What this tool does
It sizes one single-phase liquid line for up to 3 operating cases (e.g. minimum, normal, maximum) and shows up to 4 pipe sizes side by side. For every case Γ size combination you see velocity, friction pressure drop, static (elevation) pressure drop, total pressure drop, Reynolds number, flow regime and friction factor β so you can see directly what happens when you go one size up or down, and which case governs.
Step by step
- Project data β fill in project, line number, doc no. and revision. This only goes on the print and in the file name; it does not affect the results.
- Common data β pipe roughness Ξ΅, pipe length, equivalent length of fittings and valves, and the elevation change H (outlet minus inlet; + = upward). These apply to all cases.
- Design criteria β enter the limits from your project / company specification. Set a limit to
0to skip that check. - Operating cases β choose the flow basis (mΒ³/h or kg/h), then enter flow, density and viscosity per case at operating temperature. Untick use to leave a case out.
- Pipe sizes β pick NPS and schedule for each column. OD, wall thickness and ID update immediately. Untick use to hide a size.
- Press the orange βΆ CALCULATE button. Results only update when you press it. If you change an input afterwards, the results turn grey and the button pulses until you calculate again.
- Save your work as a .json file, Open it later, or Print it (landscape A4).
Reading the comparison matrix
- Green cell β within the limit. Red β exceeds the limit. Orange β transitional flow (see below).
- Governing utilisation β the highest value Γ· limit over all active cases and all checked criteria. It tells you which case and which criterion decide the size.
- β column β the smallest selected size that passes all criteria for all active cases.
- The charts show velocity, ΞP/100 m and total ΞP per size, one line per case, with the limit as a red dashed line.
Design criteria β velocity and ΞP/100 m
The defaults (max 3 m/s and max 1.0 bar/100 m) are the same as in the single-case line sizing tool and are general screening values for process liquid lines. The binding values always come from the project / company specification. Points to keep in mind:
- Pump suction lines are normally sized with a lower velocity and ΞP than discharge lines, to protect the available NPSH. Use the limits from your specification for suction service.
- Gravity / self-draining lines and lines with solids or settling risk may need a minimum velocity as well β check this separately.
- Corrosive, erosive or flashing liquids, and lines with fast-closing valves (surge / water hammer), may need lower velocities.
- The ΞP/100 m criterion checks friction only. The static head from elevation is reported separately and added to the total ΞP.
Elevation β static pressure drop
ΞPstatic = ΟΒ·gΒ·H / 10β΅ [bar], with H = outlet elevation minus inlet elevation. A positive H (upward flow) adds to the pressure drop; a negative H (downward flow) gives a pressure gain and reduces the total ΞP. The static ΞP is the same for every pipe size, so it does not influence the size selection β but it matters for the total pressure balance (e.g. pump head).
Flow regime β laminar and transitional flow
- Turbulent (Re > 4000): normal for most process liquids; the Churchill (1977) friction factor is used.
- Transitional (Re 2300β4000): the friction factor is uncertain and ΞP can vary considerably. The cell is marked orange and a note lists the affected combinations β apply a margin.
- Laminar (Re < 2300): f = 64/Re. ΞP is then proportional to viscosity, so use viscosity at the actual operating temperature (viscous oils, glycols, cold service).
Limitations
- Single-phase, incompressible, Newtonian liquid with constant properties per case.
- No check on NPSH, flashing or cavitation, surge / water hammer, or minimum velocity for solids.
- Not suitable for two-phase flow or slurries, or for non-Newtonian fluids.
- Results are for preliminary engineering and must be verified by a qualified process engineer.