PRESSURE READING
This value is
Standard atmosphere = 1.01325 bar. Use the local barometric pressure if you know it.
Fills in the atmospheric pressure above from the standard atmosphere.
A pressure difference (ΔP) is the same in gauge and absolute.
Only add atmospheric pressure to a pressure, never to a pressure drop.
Vacuum is usually written as a negative gauge pressure: −0.5 barg = 0.513 bara.
MASS ↔ VOLUME
Convert a
Density at the actual temperature. SG is taken as density ÷ 1000 kg/m³.
For liquids. Use the density at flowing or storage temperature, not at 15 °C, unless you want the volume at 15 °C.
Gas density changes strongly with pressure and temperature, so for gases work with normal or standard volumes (Nm³/h, SCFM) instead.
HEAD ↔ PRESSURE
Density at pumping temperature. SG is taken as density ÷ 1000 kg/m³.
Head is in metres of the liquid being pumped, not metres of water.
A centrifugal pump gives the same head on any liquid, but the pressure rise scales with density:
100 m of head is 9.81 bar on water and 8.34 bar on a liquid of 850 kg/m³.
Standard gravity g = 9.80665 m/s².
DYNAMIC ↔ KINEMATIC VISCOSITY
Density at the same temperature as the viscosity. SG is taken as density ÷ 1000 kg/m³.
Viscosity and density must be at the same temperature.
Dynamic (absolute) viscosity μ is what pressure drop and Reynolds number formulas use; kinematic viscosity ν is what most oil data sheets report.
For water at 20 °C the two numbers are almost equal: 1.0 cP ≈ 1.0 cSt.
°API ↔ SG ↔ DENSITY
Only used between SG and density (density = SG × water density). Set to water at 60 °F when the input or the result is °API.
No temperature correction. °API and °Baumé are defined at 60 °F (15.56 °C), so the density you get is the density at 60 °F.
A higher °API means a lighter liquid; water is 10 °API. °Baumé has two scales, one for liquids lighter than water and one for heavier.
GAS CONCENTRATION
g/mol
The temperature and pressure at which the m³ of gas is counted.
°C
bar abs
For gases, ppm here means ppmv (parts per million by volume), equivalent to mole fraction × 10⁶ for an ideal gas mixture.
ppmv itself is independent of temperature and pressure, while mass concentration (mg/m³) depends on the stated reference temperature and absolute pressure.
Ideal-gas behaviour is assumed. No correction is applied for wet/dry basis or reference oxygen content.
For liquids, ppm is commonly expressed on a mass basis, where 1 ppm = 1 mg/kg; this is a different conversion.
VALVE FLOW COEFFICIENT
Same valve, different unit system.
Cv is the flow of water in US gal/min at a pressure drop of 1 psi, typically referenced at 60 °F.
Kv is the flow of water in m³/h at a pressure drop of 1 bar, typically referenced at 20 °C.
Av is the SI coefficient in m². European valve data sheets usually quote Kv or Kvs (Kv at full opening).